YG141 fabric type digital thickness meter Caution
Information Sources: | Release date:
2016-02-26
| Pageviews:
Key words:
When you purchase our company's YG141
fabric type digital gauge, then please be sure to note the following points.
When you first get the instrument, it should be the instrument out of the box and check the instrument at the factory to prevent vibration damage in transit, the lever device with a rope tied firmly, after the solution out of the box should rope. Although the instrument in the factory have to undergo a rigorous testing and debugging, and properly packaged, but may still be subject to severe vibrations during transport caused by unpredictable damage, it is necessary prior to use to check the following items, specific projects may see random inspection instructions. If there is no problem, you can turn on the power, after pressing the start button to see all the action is normal, if the above checks all qualified, the instrument can be used normally. Also before using the instrument, please read and understand all instructions and save the good. If you still have questions or problems can not be solved in reading the manual, please refer to the Company.
Secondly instrument should pay attention to what the laboratory environment, it is in fact a normal level of general laboratory work surfaces can meet the requirements of the instrument can be put into use as long as the balance is placed on the table. Accordance with the provisions related to the sample preparation GB / T3820-1997, and the instrument reference plate around a space, it is generally measured thickness does not necessarily require a sample cut. This instrument is only one person can operate independently of each test data recorded by the operator, and then organized into a test report.
If the instrument when not in use temporarily, then you need to carry out proper maintenance of the instrument. The instrument is simple structure, reliable, easy maintenance, use should be taken to prevent dust, oil, water or other liquid intrusion, and do cleaning work, with the bad with the lights change. The instrument transmission part adopts dust rolling bearing, in order to ensure flexibility of its action, the use of oil lubrication watches, clocks necessary, to add a small amount of oil, if found sluggish action, please open the cleaning after installation and adjustment to ensure test accuracy.
If the instrument has been used for a long time, then the instrument needs to make the necessary verification, and can be tested according to the situation of working time, defined as six months or a year. Specifically, how verification method visible random instructions, if you do not understand feel free to contact our sales staff.
Finally, there is a few tips:
Power Source The instrument shall have a good grounding in order to ensure safe operation and equipment.
When the instrument is not in use or replace the presser foot to protect the foam pad is placed between the presser foot and the base plate to protect the working surface from damage.
Avoid oil, water or other liquid intrusion digital display in the table, otherwise it may cause damage to the instrument.
Avoid high temperature, high humidity environments, the working temperature should be between 0 ℃ ~ 40 ℃, relative humidity ≤80%, so as not to affect the accuracy of the instrument.
DRO when unused for long periods, remove the batteries.